ADwin-X-A20 – for series, even with ADsim

ADwin-X-A20ADwin-X-A20 was developed as a module for applications in series products. It offers compact performance and numerous interfaces. ADwin-X-A20 is the basis for your OEM applications and can be adapted to the requirements of your series. ADwin-X-A20 is housed in a robust metal enclosure and can be installed in a control cabinet or used as a portable device.

With the standard version and the ordering options, ADwin-X-A20 can be quickly integrated into small and large series production. It uses a processor similar to the one in the ADwin-Pro II system, which provides high computing power and plenty of memory.

The real-time programs are developed with ADbasic, ADwinC or from a Simulink model (ADsim).

Standard version

Schematic diagram with all options
Schematic diagram with all options
(click to open)
  • CPU: XILINX ZYNQ™ with dual-core ARM Cortex-A9, 64-bit FPU (double precision), 32-bit integer,
    666 MHz, 1 gigabyte main memory for code and data
  • Ethernet interface (1000Mbit/sec) for PC communication
  • 8 analog inputs 18 bits (MUX 5 µs), ±10V
  • 2 analog outputs 16-bit DAC (3 µs), ±10V
  • 8 TTL digital channels, switchable in groups of 4 as inputs/outputs
  • 1 trigger input (event), pos. TTL logic
  • Serial LS bus interface, see HSM-24V module for 24 volt digital signals
  • Dimensions: 215 × 125 × 47 mm

Ordering options ADwin-X-A20

X-A20 provides 8 analog inputs, conversion is performed via ADC with 18-bit resolution.
With order option F, all channels can be recorded synchronously; with the standard option M1, one channel is converted.

Analog inputs

  • 8 analog inputs with 18 bit ADC
  • Synchronous acquisition of up to 8 measured values
  • Conversion time 1.25 µs for 1 channel (5 µs for 8 channels)
  • Adjustable gain

Analog outputs

  • 8 analog outputs with 18 bit ADC
  • Channel selection and signal conversion via multiplexer
  • Conversion time 5 µs

The counter options D, C, and T can be combined with each other.
Each counter block in a counter order option contains one 32-bit forward/reverse counter and one PWM (pulse width modulation) counter. The counters in a block can be used independently of each other.

Diff. counters

  • 2 counter blocks, differential counter inputs
  • 6 differential digital channels (alternative use as counter inputs),
    2 differential digital channels
  • 1 SSI interface

Comparator counters

  • 2 counter blocks, comparator counter inputs
  • 12 comparator digital inputs (alternative use as counter inputs)
  • Edge monitoring on digital inputs (input FIFO)
  • Automatic level output on digital outputs (output FIFO)

TTL counters

  • 2 counter blocks, TTL counter inputs
  • 32 TTL digital channels (6 of which can be used alternatively as counter inputs)

Diff., TTL, and comparator counters

  • 2 counter blocks, differential counter inputs
  • 2 counter blocks, TTL counter inputs
  • 2 counter blocks, comparator counter inputs
  • 6 differential digital channels (alternative use as counter inputs),
    2 differential digital channels
  • 32 TTL digital channels (6 of which can be used alternatively as counter inputs)
  • 12 comparator digital inputs (alternative use as counter inputs)
  • Edge monitoring on digital inputs (input FIFO)
  • Automatic level output on digital outputs (output FIFO)
  • 1 SSI interface

CAN high-speed

  • 2 CAN interfaces, high-speed
  • 2 Sub-D connectors, 9-pin
  • Specification CAN 2.0 part A+B, ISO 11898
  • CAN identifier 11 bits / 29 bits
  • Bus frequency up to 1 MHz

RSxxx

  • 1 RSxxx interface
  • Operation with RS232 without/with handshake or RS485
  • 5…8 data bits, 1…2 stop bits, parity bit
  • 35 baud…2.3 Mbaud

An interface module can be plugged into ADwin-X-A20. The interface modules can be exchanged, but cannot be used at the same time.

Profi-SL

  • Plug-in interface module
  • 1 fieldbus node: Profibus slave
  • D-Sub socket, 9-pin
  • Data ranges for inputs and outputs configurable up to 61 double words

Profinet-IO

  • Plug-in interface module
  • 1 fieldbus node: Profinet IO slave
  • Connectors:
    • IRT-CU option: RJ-45 Ethernet connector
    • IRT-FO option: SC-RJ fiber optic duplex connector
  • Data ranges for inputs and outputs configurable up to 1280 bytes

EtherCAT

  • Plug-in interface module
  • 1 fieldbus node: EtherCAT slave
  • 2 RJ-45 Ethernet connectors for input and output
  • Data ranges for inputs and outputs configurable up to 254 bytes

With the bootloader, Gold III can automatically execute a program after being switched on. This allows operation without a PC.

Bootloader

  • Starts up to 10 processes after switching on
  • Operates independently of the PC
  • Can store up to 16,000 values in flash memory